| Property | Specification Requirement | Test Method | Typical Value |
|---|---|---|---|
| Longitudinal change | -10%~10% | ASTM D2671 | Pass |
| Tensile strength | ≥17.3MPa | ASTM D2671 | ≥26MPa |
| Volume resistivity | ≥1011Ω•cm | ASTM D2671 | ≥1011Ω•cm |
| Dielectric voltage withstand | AC2500V/60S No breakdown |
ASTM D2671 | No breakdown |
| Elongation at break | ≥300% | ASTM D2671 | ≥300% |
| Heat shock | No cracking | ASTM D2671 (275˚C/4 hrs) |
No cracking |
| Low temperature flexibility | No cracking | ASTM D2671 (-55˚C/4 hrs) |
No cracking |
| Elongation at break after aging | ≥100% | ASTM D2671 (225˚C/168 hrs) |
≥100% |
| Corrosion | No corrosion | ASTM D2671 | Pass |
| Excellent electrical insulation properties | |||
| No heavy metals contained | |||
| Compatibility with gamma rays and ETO sterilization | |||
| Part Number | Nominal Size | As supplied (mm) |
After recovered (mm) |
Standard Length (Meter) |
|
|---|---|---|---|---|---|
| mm | I.D. (min) |
I.D. (max) |
W.T. | ||
| MTC-0012 | 1.2 | 1.2 | 0.6 | 0.25±0.05 | 200 |
| MTC-0016 | 1.6 | 1.6 | 0.8 | 0.25±0.05 | 200 |
| MTC-0024 | 2.4 | 2.4 | 1.2 | 0.25±0.05 | 200 |
| MTC-0032 | 3.2 | 3.2 | 1.6 | 0.25±0.05 | 200 |
| MTC-0048 | 4.8 | 4.8 | 2.4 | 0.25±0.05 | 100 |
| MTC-0064 | 6.4 | 6.4 | 3.2 | 0.30±0.08 | 100 |
| MTC-0095 | 9.5 | 9.5 | 4.8 | 0.30±0.08 | 100 |
| MTC-0127 | 12.7 | 12.7 | 6.4 | 0.30±0.08 | 100 |
| MTC-0191 | 19.1 | 19.1 | 9.5 | 0.43±0.08 | 50 |
| MTC-0254 | 25.4 | 25.4 | 12.7 | 0.48±0.10 | 50 |